Local Law 126 explained: NYC parking garage inspections: the short answer

Local Law 126 requires NYC parking structure owners to have a Qualified Parking Structure Inspector file a condition assessment report at least every six years, rated Safe, SREM or Unsafe. A SREM condition not repaired by the next cycle becomes Unsafe. Sub-cycle 1C, covering the Bronx, Queens and Staten Island, runs from Jan 1, 2026 to Dec 31, 2027.

Last checked Nov 7, 2026. Source: NYC DOB Parking Structures page.

Key facts

Every 6 years
Parking structure owners must hire a New York State licensed Professional Engineer who is a Qualified Parking Structure Inspector (QPSI) to inspect the structure and file a condition assessment report with DOB at least once every six years. (NYC DOB Parking Structures page, checked Nov 7, 2026)
Dec 31, 2023
Local Law 126 sub-cycle 1A, Manhattan Community Districts 1 to 7, ran from Jan 1, 2022 to Dec 31, 2023. (NYC DOB Parking Structures page, checked Nov 7, 2026)
Dec 31, 2025
Local Law 126 sub-cycle 1B, Manhattan Community Districts 8 to 12 and all Brooklyn Community Districts, ran from Jan 1, 2024 to Dec 31, 2025. (NYC DOB Parking Structures page, checked Nov 7, 2026)
Dec 31, 2027
Local Law 126 sub-cycle 1C, covering every community district in the Bronx, Queens and Staten Island, runs from Jan 1, 2026 to Dec 31, 2027. (NYC DOB Parking Structures page, checked Nov 7, 2026)
Aug 1, 2024
Owners in sub-cycles 1B and 1C had to file a one-time initial observation by a QPSI by Aug 1, 2024 under 1 RCNY 103-16, unless a full report was filed first. (NYC DOB Parking Structures page, checked Nov 7, 2026)
60 days
The QPSI must submit the condition assessment report to DOB within 60 days of completing the assessment, with the filing fee. (NYC DOB Parking Structures page, checked Nov 7, 2026)
Becomes Unsafe
A condition reported as SREM (Safe with Repairs and Engineering Monitoring) that is not corrected by the next inspection must be reported as Unsafe. (NYC DOB Parking Structures page, checked Nov 7, 2026)
90 days
Owners must repair Unsafe conditions in a parking structure within 90 days of filing the condition assessment report, then file an amended report within two weeks of finishing the work. (NYC DOB Parking Structures page, checked Nov 7, 2026)
1,550 garages
As of Nov 5, 2026, our count of DOB open data showed 1,550 parking structures with an active Unsafe or SREM filing status. Status on file, not proof the repair is still open. (NYC Open Data, DOB NOW: Safety parking structure filings, checked Nov 5, 2026)

Who Local Law 126 covers

Local Law 126 of 2021 applies to parking structures in New York City. Parking structure owners must hire a New York State licensed Professional Engineer who is a Qualified Parking Structure Inspector (QPSI) to inspect the structure and file a condition assessment report with DOB at least once every six years. DOB runs the program under rule 1 RCNY 103-16, and the report is filed in DOB NOW: Safety.

A parking structure, for this law, is a building or part of a building used for parking or storing motor vehicles. That takes in standalone public garages, the garage levels under or beside an apartment building, and the parking decks attached to offices, hospitals and shopping centers. The law is about the structure that carries the cars, not the business of parking them. DOB lists the exemptions on its parking structures page, which cover some small private garages and open lots with no structure to inspect. The owner is responsible for knowing whether the structure qualifies.

The law followed a run of garage collapses and partial collapses in the city. The pattern was the same each time: decades of road salt, water and freeze-thaw cycles working on concrete slabs and the steel inside them, with no inspection regime to catch it. Local Law 126 was written to put parking structures on a periodic inspection cycle, the way Local Law 11 did for facades.

Who inspects

The inspection is called a condition assessment and only a Qualified Parking Structure Inspector may do it. A QPSI is a New York State licensed Professional Engineer with the experience DOB requires. The owner hires the QPSI. The QPSI inspects the structure, writes the condition assessment report, assigns the rating and files the report with DOB under their own license. The QPSI must submit the condition assessment report to DOB within 60 days of completing the assessment, with the filing fee.

The QPSI, not the owner and not a contractor, decides the rating. A contractor's opinion that a slab is spalling has no standing in the program. What has standing is the rating the QPSI filed and the date it was filed. That is the record a garage lead is built on.

The three ratings

Every condition assessment report classifies the structure one of three ways:

RatingWhat it meansWhat the owner must do
SafeNo conditions found that are unsafe or need repair before the next cycle.File the report. Nothing else until next cycle.
SREMSafe with Repairs and Engineering Monitoring. Safe to use now, but conditions need repair and the QPSI has set out engineering monitoring.Make the repairs and follow the monitoring program before the next inspection.
UnsafeA condition that is a hazard to the public or to occupants.Put up protection as the QPSI directs. Repair within 90 days. File an amended report within two weeks of finishing.

SREM is the rating that matters most over time. A condition reported as SREM (Safe with Repairs and Engineering Monitoring) that is not corrected by the next inspection must be reported as Unsafe. The rating is named differently from FISP's SWARMP but works the same way: a deferred repair does not stay deferred. It converts to Unsafe at the next filing, with the shorter repair window and the penalties that follow. The SWARMP vs Unsafe guide covers the facade version of that rule.

The sub-cycle table

The first inspection cycle is split into three two-year sub-cycles by borough and community district. Every parking structure files once in its sub-cycle, then again six years later.

Sub-cycleCoversFiling window
1AManhattan Community Districts 1 to 7Jan 1, 2022 to Dec 31, 2023
1BManhattan Community Districts 8 to 12 and all Brooklyn Community DistrictsJan 1, 2024 to Dec 31, 2025
1CEvery community district in the Bronx, Queens and Staten IslandJan 1, 2026 to Dec 31, 2027

Sub-cycles 1A and 1B have closed. Any garage in Manhattan or Brooklyn that has not filed is now late, and the status on file with DOB shows it. Sub-cycle 1C is open now and runs to the end of 2027. The Bronx, Queens and Staten Island between them hold most of the city's larger standalone garages and the parking decks under outer-borough apartment complexes, so 1C is the busiest window in the cycle.

Initial observations

Owners in the later sub-cycles did not get to wait for their window with no record on file. Owners in sub-cycles 1B and 1C had to file a one-time initial observation by a QPSI by Aug 1, 2024 under 1 RCNY 103-16, unless a full report was filed first. An initial observation is a lighter check than a full condition assessment. It gave DOB a first look at the condition of every structure in 1B and 1C before the full reports came in, and it gave owners an early warning where a QPSI saw a problem.

For a garage in 1C, that means there may already be two records on file: the initial observation from 2024 and, from this year, the full condition assessment. Where the observation flagged a concern and nothing has been done since, the full report is the point at which it becomes a dated obligation.

What happens after an Unsafe or SREM filing

An Unsafe rating starts a fixed sequence. The QPSI identifies the hazard and tells the owner what protection is needed, which can mean closing part of the deck, shoring, or taking a level out of service. The report is filed with DOB. Owners must repair Unsafe conditions in a parking structure within 90 days of filing the condition assessment report, then file an amended report within two weeks of finishing the work. If the work cannot be finished in time, the engineer requests an extension from DOB.

A SREM rating starts a slower sequence. The QPSI's report sets out the repairs and the monitoring that goes with them. The owner is expected to complete the repairs before the next inspection. There is no 90-day clock, but there is a hard stop: whatever is still unrepaired at the next inspection gets filed as Unsafe, and then the 90-day clock starts.

Both ratings end the same way. Once the repairs are done, the QPSI inspects the work and the owner files an amended report. The report is due within 60 days of the QPSI finishing the assessment, and the filing fee is paid at the same time. DOB publishes the civil penalties for late and missing reports on its parking structures page.

As of Nov 5, 2026, our count of DOB open data showed 1,550 garages with an active Unsafe or SREM filing status. That is status on file, not proof the repair is still open. The NYC parking garages data page keeps that count current.

What this means if you sell garage work

The inspecting engineer usually designs the repair and runs the bid. If you hear about a job from the QPSI, you are one of several firms on a list the engineer drew up. If you hear about it from the filing, you are talking to the owner before the list exists.

Every Unsafe filing is a dated, public obligation to repair a specific structure within 90 days. Every SREM filing is the same obligation on a longer fuse, with a conversion to Unsafe at the next cycle if nothing happens. The filings are published on NYC Open Data as DOB NOW: Safety parking structure filings. Garage owners tend to be LLCs and REITs, so the useful contact is the registered owner entity and managing agent on file with the City, not the name on the garage sign.

The same cycle logic applies to facades under Local Law 11 and to gas piping under Local Law 152. The garage program is the youngest of the three and the one with the least competition for the filings. The parking garage feed is the weekly list of new Unsafe and SREM filings with the owner on file.

Numbers behind this guide: NYC parking garages with Unsafe or SREM status.

Fair questions

Questions people ask

What is Local Law 126?

Local Law 126 of 2021 is the NYC law that requires owners of parking structures to have them inspected by a Qualified Parking Structure Inspector and to file a condition assessment report with DOB at least once every six years. DOB runs it under rule 1 RCNY 103-16.

How often is a parking garage inspected under Local Law 126?

At least once every six years. Each six-year cycle is split into three two-year sub-cycles by borough and community district, so a given garage has one two-year window per cycle.

What does SREM mean?

Safe with Repairs and Engineering Monitoring. The structure is safe to use now but has conditions that need repair and engineering monitoring. If a SREM condition is not corrected by the next inspection, it must be reported as Unsafe.

When is sub-cycle 1C due?

Sub-cycle 1C covers every community district in the Bronx, Queens and Staten Island. It runs from Jan 1, 2026 to Dec 31, 2027.

What happens if a garage is rated Unsafe?

The owner must repair the Unsafe conditions within 90 days of filing the condition assessment report, then file an amended report within two weeks of finishing the work.

Sources

  1. NYC DOB Parking Structures page checked Nov 7, 2026
  2. NYC Open Data, DOB NOW: Safety parking structure filings checked Nov 7, 2026